| NO. |
Title |
| FL33 |
ETHANOL MEASUREMENT AND ENZYME ASSAY WITH USE OF AUTOMATIC 4-TURRET ACCESSORY The F-7000 fluorescence spectrophotometer achieves a high sensitivity (S/N 800:RMS), ultra-high-speed (60,000nm/min) wavelength scan at the highest level in its class, with a wide dynamic range up to 6 digits. Furthermore, it is applied to research, development, and quality control in a broad range of fields, such as industrial materials, life sciences, and biotechnology.
The 4-turret accessory used in this experiment automatically measures, by computer control, the time course of the fluorescence intensity at regular time intervals through 4 rotating cells installed in a turret. A reaction trace for an enzyme is used to measure the time course of fluorescence intensity in plural samples. Previously, the time course was measured for one sample at a time, so the measurement time required was proportional to the number of samples. Application of the automatic 4-turret accessory reduces measurement time.
An enzyme assay was applied to ethanol measurement in this experiment. The amount of ethanol in the fish is increased according to a decline of the freshness, so this measurement is referred to as the freshness index. Ethanol is usually measured with a spectrophotometer. When ethanol is present in trace amounts, a low concentration measurement is performed with a fluorescence spectrophotometer. In this experiment, the general enzyme assay reagent “F-kit ethanol (J.K.International)” was used. In addition to the enzyme assay, a spectrophotometer was used to measure ethanol amounts. The analysis conditions were optimized, and an analytical curve for a standard solution was created.
Model: F-7000 |
| FL32 |
FLUORESCENCE SPECTRUM MEASUREMENT METHOD ALLOWING A COMPARISON OF DIFFERENT EQUIPMENT - SPECTRAL CALIBRATION OF INSTRUMENTAL RESPONSE AND VALIDATION METHOD, AND MEASUREMENT EXAMPLE FOR A STANDARD FLUORESCENT MATERIAL - |
| Model: |
F-7000 |
| Keywords: |
Fluorescence spectrum, Spectrum calibration, Instrumental response, Rhodamine B, Quinine sulfate, Standard material, GLP/GMP program |
|
| FL31 |
DETECTION OF INTERACTION BETWEEN RECEPTOR PROTEINS DEPENDING ON BIOLUMINESCENCE RESONANCE ENERGY TRANSFER |
| Model: |
F-4500 |
| Keywords: |
Fluorescence, Luminescence, HEK Cell, Protein Interaction, Receptor, Bioluminescence Resonance Energy Transfer, BRET, FRET, Luminescence resonance energy transition, GFP, YFP, ATP, G-protein |
|
| FL30 |
FLUORESCENCE POLARIZATION METHOD APPLIED TO BIOCHEMICAL STUDY
- DETERMINATION OF PCR PRODUCT - |
| Model: |
F-4500 |
| Keywords: |
Fluorescence polarization accessory, Biochemistry, DNA, RNA, PCR |
|
| FL29 |
FLUORESCENCE POLARIZATION METHOD APPLIED TO BIOCHEMICAL STUDY |
| Model: |
F-4500 |
| Keywords: |
Fluorescence polarization method, Biochemistry, Molecular weight, Enzyme activity, Trypsin, Cytoplasmic steaming |
|
| FL28 |
AUTOMATIC FLUORESCENCE SPECTROPHOTOMETRIC ASSAYS FROM MICROTITER PLATES |
| Model: |
F-4500 |
| Keywords: |
Trace sample, Mictotiter plates, Enzyme activity measurement, Automation |
|
| FL27 |
HIGHLY SENSITIVE DETERMINATION OF TERBIUM IN YTTRIUM OXIDE |
| Model: |
F-4500 |
| Keywords: |
Fluorescense determination, Terbium, Three-wavelength calculation |
|
| FL26 |
MEASUREMENT EXAMPLES OF FLUORESCENT WHITE SAMPLES |
| Model: |
F-4500 |
| Keywords: |
Fluorescent whitening agent, Whiteness, Spectral reflected radiance factor, Spectral total radiance factor |
|
| FL25 |
AN ADVANCED FLUORESCENCE SPECTROPHOTOMETRIC MEASURING SYSTEM FOR RAPID ACQUISITION OF THREE DIMENSIONAL SPECTRA |
| Model: |
F-4500 |
| Keywords: |
3-dimensional fluorescence spectra, High speed data acquisition, Petroleum, Serotonin |
|
| FL24 |
THE DETERMINATION OF CORRECTED EXCITATION SPECTRA, CORRECTED EMISSION SPECTRA AND QUANTUM YIELDS |
| Model: |
F-4010 |
| Keywords: |
Spectrum correction, Correction factor, Quantum yield, Quinine sulfate, Emission spectra, Excitation spectra |
|
| FL23 |
MEASUREMENT OF COUMARIN BY FLUORESCENCE ANALYSIS |
| Model: |
F-2000 |
| Keywords: |
Coumarin, Kerosene, Light oil |
|
| FL22 |
MEASUREMENT OF CYTOSOLIC Ca2+ IN THE INITIAL GROWTH OF MOUSE FIBROBLAST CELLS |
| Model: |
F-2000 |
| Keywords: |
PIP2, PDE, IP3, BALB/C 3T3 |
|
|
|