Applications : Potentiometric Titrator |
We introduce you to plenty of data on analytical methods and their results using our Potentiometric Titrator.
If you have any questions, please contact us by e-mail (Inquiry Form).
 |
Metal |
| |
| NO. |
Title |
| ME09 |
Quantification of lead ion (Pb2+) |
Model: COM-1700/1750 , COM-1600 |
| ME08 |
Quantification of lanthanum (La3+) |
Model: COM-1700/1750 , COM-1600 |
| ME07 |
Quantification of manganese ion (Mn2+) |
Model: COM-1700/1750 , COM-1600 |
| ME06 |
Quantification of ferrous ion (Fe2+) and ferric ion (Fe3+) in steel plate washing solution |
Model: COM-1700/1750 , COM-1600 |
| ME05 |
Quantification of ferric ion (Fe3+) when chromic anhydride is contained |
Model: COM-1700/1750 , COM-1600 |
| ME04 |
Quantification of Ni2+ in mixed solution of Ni2+ and Cu2+ |
Model: COM-1700/1750 , COM-1600 |
| ME03 |
Quantification of fluorine, bromine and chlorine in solder flux |
Model: COM-1700/1750 , COM-1600 |
| ME02 |
Quantification of trace chlorine ion (Cl-) in copper sulfate solution |
Model: COM-1700/1750 , COM-1600 |
| ME01 |
Quantification of zinc ion (Zn2+) |
Model: COM-1700/1750 , COM-1600 |
|
|
 |
Food and Bevarege |
| |
| NO. |
Title |
| FB08 |
Measurement of saponification value in edible oil |
Model: COM-1700/1750 , COM-1600 |
| FB07 |
Measurement of iodine number in edible oil |
Model: COM-1700/1750 , COM-1600 |
| FB06 |
Measurement of acid value of edible oil |
Model: COM-1700/1750 , COM-1600 |
| FB05 |
Successive measurement of amino nitrogen and acid (citric acid) in grapefruit juice |
Model: COM-1700/1750 , COM-1600 |
| FB04 |
Successive measurement of citric acid and vitamin C in refreshing drinks |
Model: COM-1700/1750 , COM-1600 |
| FB03 |
Titration of citric acid in plum (Japanese apricot) juice |
Model: COM-1700/1750 , COM-1600 |
| FB02 |
Successive titration of acid and salt in dressings |
Model: COM-1700/1750 , COM-1600 |
| FB01 |
Measurement of salt in soy sauce |
Model: COM-1700/1750 , COM-1600 |
|
|
 |
Pharmaceuticals |
| |
| NO. |
Title |
| PH18 |
Measurement of pKa for medical products |
Model: COM-1700/1750 , COM-1600 |
| PH17 |
Quantification of chlorine in bethanechol chloride |
Model: COM-1700/1750 , COM-1600 |
| PH16 |
Quantification of iothalamic acid by precipitation titration |
Model: COM-1700/1750 , COM-1600 |
| PH15 |
Quantification of sodium chloride in peritoneal dialytic fluid |
Model: COM-1700/1750 , COM-1600 |
| PH14 |
Quantification of sodium edentate (EDTA・2Na) in preparations |
Model: COM-1700/1750 , COM-1600 |
| PH13 |
Quantification of calcium and magnesium in dialytic fluid and transfusion |
Model: COM-1700/1750 , COM-1600 |
| PH12 |
Measurement of sulfamethizole purity by diazotization titration |
Model: COM-1700/1750 , COM-1600 |
| PH11 |
Measurement of sodium sulfisozole purity by diazotization titration |
Model: COM-1700/1750 , COM-1600 |
| PH10 |
Measurement of 3-amino-N-methylbenzamid (AMB) purity by diazotization titration |
Model: COM-1700/1750 , COM-1600 |
| PH09 |
Evaluation of titer of sodium nitrite titrant with sulfamic acid |
Model: COM-1700/1750 , COM-1600 |
| PH08 |
Measurement of pantethine purity |
Model: COM-1700/1750 , COM-1600 |
| PH07 |
Quantification of iodine in mouth wash |
Model: COM-1700/1750 , COM-1600 |
| PH06 |
Measurement of cetraxate hydrochloride purity |
Model: COM-1700/1750 , COM-1600 |
| PH05 |
Measurement of hymecromone purity |
Model: COM-1700/1750 , COM-1600 |
| PH04 |
Quantification of bethanechol chloride by perchloric acid titration |
Model: COM-1700/1750 , COM-1600 |
| PH03 |
Quantification of carteolol hydrochloride with perchloric acid titration |
Model: COM-1700/1750 , COM-1600 |
| PH02 |
Quantification of sodium acetate by erchloric acid titration |
Model: COM-1700/1750 , COM-1600 |
| PH01 |
Quantification of methylbenactyzium bromide by perchloric acid titration |
Model: COM-1700/1750 , COM-1600 |
|
|
 |
Environmental |
 |
| NO. |
Title |
| EN05 |
Measurement of alkalinity of mineral water |
Model: COM-1700/1750 , COM-1600 |
| EN04 |
Measurement of residual chlorine in running water |
Model: COM-1700/1750 , COM-1600 |
| EN03 |
Titration of calcium hardness in drinking water |
Model: COM-1700/1750 , COM-1600 |
| EN02 |
Measurement of total hardness of drinking water |
Model: COM-1700/1750 , COM-1600 |
| EN01 |
Quantification of chlorine ion in drinking water |
Model: COM-1700/1750 , COM-1600 |
|
|
 |
 |
Plating |
 |
| NO. |
Title |
| PL08 |
Quantification of hydrogen peroxide and sulfuric acid in etching solution |
Model: COM-1700/1750 , COM-1600 |
| PL07 |
Quantification of zinc (Zn2+) in zinc plating solution |
Model: COM-1700/1750 , COM-1600 |
| PL06 |
Quantification of tin (Sn2+) in solder plating solution |
Model: COM-1700/1750 , COM-1600 |
| PL05 |
Quantification of lead in solder plating solution |
Model: COM-1700/1750 , COM-1600 |
| PL04 |
Quantification of chromic anhydride (CrO3) and trivalent chromium (Cr3+) in chrome plating solution |
Model: COM-1700/1750 , COM-1600 |
| PL03 |
Quantification of nickel chloride (NiCl2) in nickel plating solution |
Model: COM-1700/1750 , COM-1600 |
| PL02 |
Quantification of copper and sodium cyanide in copper cyanide plating solution |
Model: COM-1700/1750 , COM-1600 |
| PL01 |
Quantification of silver and free cyanides in silver cyanide plating solution |
Model: COM-1700/1750 , COM-1600 |
|
|
 |
 |
Electronics |
 |
| NO. |
Title |
| EL08 |
Quantification of remover in photoresist remover solution |
Model: COM-1700/1750 , COM-1600 |
| EL07 |
Quantification of free acid in lead frame treatment solution for IC |
Model: COM-1700/1750 , COM-1600 |
| EL06 |
Quantification of oxalic acid in lead frame treatment solution for IC |
Model: COM-1700/1750 , COM-1600 |
| EL05 |
Quantification of H2O2 in silicon wafer abrasive solution |
Model: COM-1700/1750 , COM-1600 |
| EL04 |
Measurement of acid value in transformer oil |
Model: COM-1700/1750 , COM-1600 |
| EL03 |
Quantification of trace chlorine ion in freezer lubricant |
Model: COM-1700/1750 , COM-1600 |
| EL02 |
Quantification of trace chlorine ion in SiO2 (silicon dioxide) |
Model: COM-1700/1750 , COM-1600 |
| EL01 |
Quantification of trace chlorine ion in IC molding resin |
Model: COM-1700/1750 , COM-1600 |
|
|
 |
 |
Paper and Pulp |
 |
| NO. |
Title |
| PA10 |
Quantification of chlorine dioxide in pulp bleaching solution |
Model: COM-1700/1750 , COM-1600 |
| PA09 |
Quantification of NaOH, Na2S and Na2CO3 in pulp cooking solution |
Model: COM-1700/1750 , COM-1600 |
| PA08 |
Quantification of sodium oxide (Na2S) and silicic acid (SiO2) in sodium silicate |
Model: COM-1700/1750 , COM-1600 |
| PA07 |
Measurement of sodium chlorate (NaClO3) purity |
Model: COM-1700/1750 , COM-1600 |
| PA06 |
Quantification of sodium chloride in sodium hypochlorite |
Model: COM-1700/1750 , COM-1600 |
| PA05 |
Quantification of residual alkali in sodium hypochlorite |
Model: COM-1700/1750 , COM-1600 |
| PA04 |
Quantification of available chlorine in sodium hypochlorite |
Model: COM-1700/1750 , COM-1600 |
| PA03 |
Quantification of trace chlorine ion in sodium hydroxide |
Model: COM-1700/1750 , COM-1600 |
| PA02 |
Fractionation quantification of mixture of sodium hydroxide (NaOH) and sodium carbonate (Na2CO3) |
Model: COM-1700/1750 , COM-1600 |
| PA01 |
Measurement of sodium hydroxide purity |
Model: COM-1700/1750 , COM-1600 |
|
|
 |
 |
Inorganic Acid |
 |
| NO. |
Title |
| IN09 |
Successive quantification of cyanide and cyanic acid in metal treatment salt |
Model: COM-1700/1750 , COM-1600 |
| IN08 |
Quantification of boric acid in plating solution |
Model: COM-1700/1750 , COM-1600 |
| IN07 |
Fractionation quantification of mixture of 3 components; nitric acid, hydrofluoric acid and acetic acid |
Model: COM-1700/1750 , COM-1600 |
| IN06 |
Fractionation quantification of nitric acid andacetic acid |
Model: COM-1700/1750 , COM-1600 |
| IN05 |
Fractionation quantification of hydrochloric acid and sulfuric acid |
Model: COM-1700/1750 , COM-1600 |
| IN04 |
Fractionation quantification of nitric acid and hydrofluoric acid |
Model: COM-1700/1750 , COM-1600 |
| IN03 |
Fractionation quantification of hydrochloric acid and hydrofluoric acid |
Model: COM-1700/1750 , COM-1600 |
| IN02 |
Measurement of phosphoric acid purity |
Model: COM-1700/1750 , COM-1600 |
| IN01 |
Measurement of sulfuric acid purity |
Model: COM-1700/1750 , COM-1600 |
|
|
 |
 |
Organic Acid |
 |
| NO. |
Title |
| OR09 |
Fractionation quantification of peracetic acid and hydrogen peroxide |
Model: COM-1700/1750 , COM-1600 |
| OR08 |
Fractionation quantification of ascorbic acid and sodium ascorbate |
Model: COM-1700/1750 , COM-1600 |
| OR07 |
Fractionation quantification of acetic acid and ammonium acetate |
Model: COM-1700/1750 , COM-1600 |
| OR06 |
Quantification of phthalic acid |
Model: COM-1700/1750 , COM-1600 |
| OR05 |
Quantification of oxalic acid |
Model: COM-1700/1750 , COM-1600 |
| OR04 |
Quantification of lactic acid |
Model: COM-1700/1750 , COM-1600 |
| OR03 |
Quantification of citric acid |
Model: COM-1700/1750 , COM-1600 |
| OR02 |
Quantification of formic acid |
Model: COM-1700/1750 , COM-1600 |
| OR01 |
Measurement of acrylic acid purity |
Model: COM-1700/1750 , COM-1600 |
|
|
 |
 |
Petroleum Products |
 |
| NO. |
Title |
| PE10 |
Measurement of bromine index in aromatic compounds |
Model: COM-1700/1750 , COM-1600 |
| PE09 |
Measurement of bromine value in nonene |
Model: COM-1700/1750 , COM-1600 |
| PE08 |
Quantification of chlorides in freezer oils |
Model: COM-1700/1750 , COM-1600 |
| PE07 |
Measurement of reserve alkalinity in antifreeze |
Model: COM-1700/1750 , COM-1600 |
| PE06 |
Measurement of total acid value in turbine oils |
Model: COM-1700/1750 , COM-1600 |
| PE05 |
Measurement of total acid value in freezer oils |
Model: COM-1700/1750 , COM-1600 |
| PE04 |
Measurement of total acid value in transformer oils |
Model: COM-1700/1750 , COM-1600 |
| PE03 |
Measurement of total base value in lubricants (perchloric acid method) |
Model: COM-1700/1750 , COM-1600 |
| PE02 |
Measurement of total base value in lubricants(hydrochloric acid method) |
Model: COM-1700/1750 , COM-1600 |
| PE01 |
Measurement of total acid value in lubricants |
Model: COM-1700/1750 , COM-1600 |
|
|
 |
 |
Plating Solution |
 |
| NO. |
Title |
| PLS01 |
Plating Solution applicaction data for COM series |
Model: COM-1700/1750 , COM-1600 |
|
|
 |
|














|