
 |
HPLC System Manager
Chromaster System Manager |
 |
| Supporting the operation of Chromaster modules. |
 |
Inheriting the ease of use of the D-2000 Elite opereratability The Chromaster System Manager continues with the ease of use of D-2000 Elite which enjoys rave reviews for a long time. User friendly GUI (Graphical User Interface) assists the intuitive operation of Chromaster modules.
Quick USB connection
USB is used for the communication between PC and Chromaster modules. No special boards are required on the PC side. |
 |
Features |
| |
A tool box makes the required sequence of measurement operations easy to use |
|
| |
Simply click the icons provided in the tool box on the left side of the screen, in logical sequence from the top. The icons open the screens needed for measurement so that you can operate the system with confidence. |
 |
|
| |
Multi-control of Chromaster systems |
|
| |
One PC can control two Chromaster systems. It improves analysis efficiency and ease-of-use of the systems.
The system containing DAD is restricted one of the two systems.) |
|
| |
Auto-operation by means of sleep/wakeup features |
|
| |
These features automatically stop the operation upon termination of a continuous analysis and resume the run at a specified time.
The sleep feature can stop the pumping of solvent, halt column open temperature control, and turn off detector lamp. The wakeup feature starts the warming up (starts pumping, begins column oven temperature control, and turns on detector lamp) at a specified time. |
 |
|
| |
Deconvolution function |
|
| |
This function splits two overlapping peaks by using the Exponential Modified Gaussian (EMG) technique into two peaks to calculate their areas. The results of deconvolution can be verified either on the screen or on a report that is generated. In addition, quantitative calculations can be performed by using the areas of the peaks obtained through the splitting. This can be a powerful method of quantitation on peaks that are otherwise difficult to separate. |
 |
|
| |
 |
|
| |
Data transfer function based on an online DDE function |
|
| |
While collecting data, you can automatically transfer generated reports to Microsoft® Excel®, such as report headers, chromatograms, contour line diagrams (when connected to a DAD), calculation results, and confidence reports. Such reports can also be transferred when collected data are being recalculated. In addition, by using the attached summary macro program, it is possible to compile the results of multiple sets of data calculation in a table. This function can be useful to manage the results using Microsoft® Excel®. (Requires either Microsoft® Excel® 2010.)
*Dynamic Data Exchange |
|
| |
 |
|
| |
 |
|
| |
 |
|
| |
 |
|
| |
Peak purity verification function |
|
| |
The software can verify the purity of a given sample to ascertain whether an elution peak consists of a single component or multiple components that are difficult to separate. The software can automatically determine the purity of a sample, based upon the spectral correlation coefficients of two spots on peaks and can display results in a report. If the purity is lower than an indicated value that is entered, the system can plot the peak in red, and in green if it is higher, to produce a visually intuitive output. |
|
| |
 |
|
| |
* Chromaster System Manager is software. PC and Chromaster module(s) are required for the operation. |
|
| |
* Microsoft®, Excel® are registered trademark of Microsoft Corporation in U.S.A and other countries. |
|
 |




















|