L-2130 HTA Pump


 Modules and Specifications  Applications  Contact Us

 

L-2130 HTA Pump

 
 
  • High-accuracy flow rate for high- speed analysis
    The improved motor drive circuit expands the applicable range of flow rate accuracy of ±2% to an upper limit of 8.0 mL/min. This makes it possible to use the Chromolith TM column (manufactured by Merck) for ultra-high speed analyses at high flow rate. This pump is particularly suitable for analyses in the flow rate range of 0.5 to 8.0 mL/min.


  • Enhancements in flow rate accuracy and retention
    time reproducibility in gradient analyses
    The innovative technologies used in the L-2100 pump (SMASH) are also incorporated in this pump for providing high accuracy in flow rate and retention time reproducibility.


  • Degasser incorporated in pump unit
    The degasser can be installed inside the pump module. This eliminates an extra space for installing the degasser, thereby enabling a compact system configuration. Furthermore, solvent substitution can be made efficiently by means of minimum piping reconnection.
 
     

Specifications


Item L-2130 HTA Pump
Accuracy +/- 2 µL (0.01 to 0.10 mL/min)
+/- 2 % (0.101 to 8.000 mL/min)
+/- 4 % (8.001 to 9.999 mL/min)
Precision +/-0.075 % RSD or 0.02 min SD at 1.0 mL/min
Constant pressure 290 to 5600 psi at 0 to 5.0 mL/min
Solvent delivery 100 µL stroke
Dimensions 13.5 in (W) x 15.75 in (D) x 6.0 in (D)
(340 mm (W) x 400 mm (D) x 150 mm (D))
Weight approx. 24 lbs (11 kg)
IGHPRESSURE GRADIENT
Flow rate range 0.001 to 9.999 mL/min
(0.2 to 5.0 mL/min recommended)
Binary Up to 2 eluents
Composition range 1 to 100% (0.1% increments)
Accuracy +/- 1 % (0.2 mL/min)
Precision 0.1% RSD or 0.02 min SD at 1.0 mL/min
LOW PRESSURE GRADIENT
Flow rate range 0.001 to 9.999 mL/min
(0.2 to 5.0 mL recommended)
Quarternary Up to 4 eluents
Composition range 0 to 100% (0.1% increments with CDS; 1% increments with front panel control
Accuracy +/- 1 % (0.2 mL/min)
Precision 0.1 % RSD or 0.02 min SD at 1.0 mL/min
 

contents end
Search by Google
 > Advanced Search
Life science

Topics

Global Network

Products

starting of secondary navigation UV-Visible/NIR Spectrophotometer

starting of secondary navigation Fluorescence Spectrophotometer

starting of secondary navigation Atomic Absorption Spectrophotometer

HPLC/Amino Acid Analyzer

starting of secondary navigation Chromaster

starting of secondary navigation Chromaster Driver for Waters Empower2 Software

starting of secondary navigation Chromaster system Manager

starting of secondary navigation LaChromUltra

LaChrom Elite

starting of secondary navigation NanoFrontier nLC

starting of secondary navigation L-8900

starting of secondary navigation HPLC Columns LaChrom Series

starting of secondary navigation LCMS

starting of secondary navigation Clinical Analyzer

starting of secondary navigation Potentiometric Titrator

starting of secondary navigation Karl Fischer Titrator

starting of secondary navigation Mercury Analyzer

Applications

Contact Us

Sitemap

HPLC Basic Course
pagetop
 
starting of footer  | Terms of use | Privacy Policy | All Rights Reserved Copyright (C) 2001, 2012. Hitachi High-Technologies Corporation.
starting of footer  | Terms of use | Privacy Policy | All Rights Reserved Copyright (C) 2001, 2012. Hitachi High-Technologies Corporation.