LaChromUltra C18 Series Columns |
Hitachi Ultra High-Speed Liquid Chromatograph LaChromUltra |
 |
High Speed Analysis and Superior Resolution at Significantly Lower Pressures than Sub-2μm Columns
High speed liquid chromatography performance is a balance between many factors including particle size, system pressure and column chemistry. LaChromUltra 2μm particle size columns offer the permeability and performance to achieve ultra fast analyses with excellent chromatographic resolution but at much lower pressures than other sub-2μm particle size columns. In addition, the stable end capping make LaChromUltra columns the ideal choice for a broad range of applications. |
 |
Features |
| |
- Uses a 2-μm particle size column developed specially for ultra high-speed liquid chromatographs
- Excellent processing of the end capping make LaChromUltra columns and well-balanced seperation
- Achieve lowered pressure loss and high-speed high-seperation analysis using Sub-2μm columns
|
|
| |
|
|
| |
Example of Ultra High Speed Analysis Using Methanol as the Mobile Phase |
|
 |
| |
|
|
| |
| Sample:Tricyclic Drugs |
Analytical Conditions |
1.Carbamazepine
2.Imipramine
3.Protriptyline
4.Amitriptyline
5.Nortriptyline |
Column Temperature: 40
Mobile Phase: CH3OH/Phosphate
Buffer=45/55
Flow Rate: 0.6mL/min
Detection: UV254nm
System Pressure: 50MPa |
|
|
 |
Example of system configuration |
| |
 |
|
| |
|
|
| |
| Sample: DNPH-aldehyde |
Analytical Conditions |
1.Formaldehyde
2.Acetaldehyde
3.Acetone
4.Propionaldehyde
5.Crotonaldehyde
6.Isobutyraldehyde
7.Benzaldehyde
8.n-valeraldehyde |
Column Temperature: 40
Mobile Phase: CH3CN/H2O = 60/40
Flow Rate: 1.0mL/min
Detection: 360nm
Injection Rate: 0.5 μL |
|
|
 |
Specifications |
| |
| |
LaChromUltra C18(2μm) 2×50 |
LaChromUltra C18(2μm) 2×75 |
LaChromUltra C18(2μm) 2×100 |
| Parts No. |
891-5000 |
891-5001 |
891-5002 |
| Column Size |
2.0mmI.D.×50mmL |
2.0mmI.D.×75mmL |
2.0mmI.D.×100mmL |
| Particle Size |
Silicagel C18(2μm),End cap processing |
Silicagel C18(2μm),End cap processing |
Silicagel C18(2μm),End cap processing |
| Range of pressure |
0-50Mpa |
0-50Mpa |
0-50Mpa |
| Range of temperature |
20-50 |
20-50 |
20-50 |
|
|
| |
|
|
| |
| |
LaChromUltra C18(3μm) |
LaChromUltra C18(5μm) |
| Parts No. |
891-5030 |
891-5050 |
| Column Size |
4.6mmI.D.×100mmL |
4.6mmI.D.×150mmL |
| Particle Size |
Silicagel C18(3μm),End cap processing |
Silicagel C18(5μm),End cap processing |
| Range of pressure |
0-50Mpa |
0-50Mpa |
| Range of temperature |
20-50 |
20-50 |
|
|
Sales&Contact: