Hitachi High-Technologies
Skip to header Hitachi High-Technologies
 News & Events       Site map

Go HITACHI Top
global navigation start   | Home | About Us | Investor Relations | Global Network |  Products & Services | Customer Service |

 
breadcrumbs list start Life Science > Products > Potentiometric Titrator  >COM-1700/1750
 
contents start

COM-1700/1750 series Potentiometric Titrator

Request Quote

COM-1700 Automatic Titrators designed to meet your needs now and in the future!
Our most Intelligent and advanced titrator ever produced, the COM-1700 and COM-1750 series.
 Topic : Automatic Potentiometric Titrator COM-1700 series
The COM-1700 series titrators have been recently designed and developed and are being introduced as the next generation of automatic titrators that will provide outstanding features and benefits.
 Features  Specifications  Options
 Automatic Potentiometric Titrator COM-1700 series  Contact Us

Features


  • Now you have a choice! A stand-alone or PC-controlled system
    COM-1700 and COM-1750

  • Easily control up to 4 independent multitasking workstations.
    Additional Titration stations + Stirrers can easily allow end users to do different types of titraion including potentiometric, photometric, polarization, and conductometric titrations in parallel.
    Configuring multiple titration stations with an automatic sample changer is also available.

  • A new compact design of the buret & the titration station.
    The new design reduces bench space by 25% compared to the previous model. The new buret of the B-1700 is compatible with conventional COM series titrators.

  • Advanced functions and excellent operational performance of the COM-1700!Advanced functions and excellent operational performance
 

Specifications


Item Specifications
Main control unit COM-1700 series:COM-1700 Titrator main unit
COM-1750 series:PC(system program & PCI board)
Multitasking function Up to 4 parallel titration stations
Titration methods Potentiometric titration, Polarization titration, Photometric titration, Conductometric titration.
(*Each titration method requires a proper measurement unit respectively)
Titration mode Leam titration, Auto inflection-point detection, Set-point detection, Set/Auto end-point detection, Cross-point (F, B, V1, V2) detection, Dispensing, Neutralization value in Petroleum product (Oil1/Oil2), pH measurement, pH-Stat, pKa measurement, Calculation mode
Number of end-points Learn titration: Up to 5 end-points
Linked Conditions: Up to 5 points.
Master file Titration run files: 50
Number of linked Condition files: 9
(Up to 5 file for titration files)
Condition files Titration parameter files: 50 files
(Method, Constant, Mode files)
Method parameters Parameters for each titration mode: 50 files
Constant parameters Parameters for concentration calculation: 50 files
Control mode file Standard files: 50 files
Neutralization value in petro.File : 50files
Manufacturer preinstalled modes (0 to 11), user defined modes (20 to 49)
Sample files 99 files
(Sample No., ID code, Master file and sample size)
Auto- input function Automatic input of blank, factors, concentration measurement results, etc.
Calculation Concentration calculation, statistics calculation, pH automatic compensation
Data capacity [COM-1700] Main unit memory: 100 data
USB flash memory (within 256MB), Max. capacity approx. 9,900 data
[COM-1750] 255 data/folder (For total memory data, if hard disc space is 1GB or more, Max. capacity approx. 9,900 data)
GLP support functions Buret precision check, electrode check, Buret use frequency, electrode maintenance, remaining reagent level
Buret Expandable up to 10 burets (per 1 titration station)
Automatic sample changer [COM-1700, TS-1700] 1 set of C-1700 sample changer can be attached.
Printer [COM-1700] Bulit-in thermal printer (paper width 58mm)
[COM-1750] Color printer for A4-size paper
External output [COM-1700] RS-232C: 1 port / LAN: 1 port/USB(*1)
[COM-1750] RS-232C: 1 port / LAN: 1 port/USB (depends on PC)
Attached electrodes ·GE-101B Glass combination electrode
·RE-201 Reference electrode
(provided with COM-1700 / TS-1700)
Power supply / Power consumption [COM-1700] AC 100 - 240V, 50/60 Hz, 60 VA
[COM-1700] AC 100 - 240V, 50/60 Hz, 220 VA
Dimensions / Weight [COM-1700] 250(W) x 400(D) x 150(H) mm
Approx. 6.0 kg
[COM-1750] depends on PC configured with
 
  *1:The USB port on the COM-1700 main unit is only for use of USB flash memory for data storage. please do not connect other USB-type devices.

  Buret B-1700 / Titration Station TS-1700  
Item Specifications
Display operation B-1700: Purge switch, LED lighting-up during dispensing
TS-1700: Operation switch (LCD touch panel, wired remote controller)
Buret capacity 20 mL clear glass syringe (standard) (Options: 1,5,10,50 mL syringe)
Cylinder cover UV shield (material: acrylic) for 5,10,20 mL cylinder only
Fabrication method 5, 10, 20, and 50 mL: Inner cylinder precision grinding
1 mL: Outer cylinder precision grinding
Wet material PTFE, hard glass, ceramic
Connection tube 2 x 3 mm, PTFE tube (brown)
Reagent bottle 500 mL glass bottle (brown)
Selector valve Automatic switching with ceramic joint,
Drive motor: pulse motor
Dispensing rate Full volume: 50 - 250 sec, in 50 sec, step selting (20 mL cylinder)
Aspritating rate Full volume: 25 sec
Minimum volume of titrant 1.25 μL (20 mL cylinder)
Buret precision Accuracy: within ±0.1 %
(full discharge of 20 mL cylinder)
Repeatability: within 0.01 mL (full discharge of 20 mL cylinder, SD for n = 6)
Linkable buret number [TS-1700] Connectable up to 9 units of B-1700
Measurement unit [TS-1700] Any one of S-1700, M-1700, P-1700, or E-1700 attached
Automatic sample changer [TS-1700] 1set of C-1700 can be attached.
Attached electrodes [TS-1700] GE-101B Glass electrode, RE-201 Reference electrode
Power requirements AC 100 to 240V , 50VA
Dimensions / Weight [B-1700] 104(W) x 240 (D) x 410(H) mm
Approx. 4.0 kg (w/ Buret head (without reagent bottle)
[TS-1700] 104(W) x 325 (D) x 410(H) mm
Approx. 5.5 kg (w/ Measurement unit, Buret head(without reagent bottle))
 

  Stirrer K-2000T2  
Item Specifications
Beaker Up to 500 mL standard beaker
Stirring method Magnetic stirrer
Stirring bar 8 x 30 mm, PTFE-coated magnet (1 piece attached)
Rotation speed selting Adjustable resistor
Number of attachable electrode & buret tip 1. Electrodes: Up to 2
2. Thermister electrode: 1
3. Buret tip: Up to 3
4. Dispenser nozzle: 1
Power requirements DC 12V (power supplied from the titrator main unit)
Dimensions / Weight 110(W) x 210(D) x 350(H) mm
Approx. 1.0 kg
 


Options


Model
For Potentimetric titration S-1700
For Photometric Titration M-1700
For Polarization Titration P-1700
For Conductometric Titration E-1700
Dot Impact Printer PR-302B Paper width:58mm
Automatic samle changer C-1712

  * The product color may vary from the actual product due to printing qualities.  
  * Appearance, specification, etc. are subject to change for improvement without prior notice.  
  Note: For safe and appropriate use, please be sure to read the "Instruction Manual" before using the product.  

Request Quote
contents end
Search by Google
 > Advanced Search
Life science

Topics

Global Network

Products

starting of secondary navigation UV-Visible/NIR Spectrophotometer

starting of secondary navigation Fluorescence Spectrophotometer

starting of secondary navigation Atomic Absorption Spectrophotometer

starting of secondary navigation HPLC/Amino Acid Analyzer

starting of secondary navigation LCMS

starting of secondary navigation Clinical Analyzer

Potentiometric Titrator

COM-1700/1750

starting of secondary navigation Karl Fischer Titrator

starting of secondary navigation Mercury Analyzer

Applications

Contact Us

Sitemap


pagetop
 
starting of footer  | Terms of use | Privacy Policy | All Rights Reserved Copyright (C) 2001, 2012. Hitachi High-Technologies Corporation.
starting of footer  | Terms of use | Privacy Policy | All Rights Reserved Copyright (C) 2001, 2012. Hitachi High-Technologies Corporation.