COM-1700/1750 series Potentiometric Titrator |
 |
 |
Automatic Titrators designed to meet your needs now and in the future!
Our most Intelligent and advanced titrator ever produced, the COM-1700 and COM-1750 series. |
 |
Features |
|
- Now you have a choice! A stand-alone or PC-controlled system

- Easily control up to 4 independent multitasking workstations.
Additional Titration stations + Stirrers can easily allow end users to do different types of titraion including potentiometric, photometric, polarization, and conductometric titrations in parallel. Configuring multiple titration stations with an automatic sample changer is also available.
- A new compact design of the buret & the titration station.
The new design reduces bench space by 25% compared to the previous model. The new buret of the B-1700 is compatible with conventional COM series titrators.
- Advanced functions and excellent operational performance of the COM-1700!

|
|
 |
Specifications |
|
| Item |
Specifications |
| Main control unit |
COM-1700 series:COM-1700 Titrator main unit COM-1750 series:PC(system program & PCI board) |
| Multitasking function |
Up to 4 parallel titration stations |
| Titration methods |
Potentiometric titration, Polarization titration, Photometric titration, Conductometric titration. (*Each titration method requires a proper measurement unit respectively) |
| Titration mode |
Leam titration, Auto inflection-point detection, Set-point detection, Set/Auto end-point detection, Cross-point (F, B, V1, V2) detection, Dispensing, Neutralization value in Petroleum product (Oil1/Oil2), pH measurement, pH-Stat, pKa measurement, Calculation mode |
| Number of end-points |
Learn titration: Up to 5 end-points Linked Conditions: Up to 5 points. |
| Master file |
Titration run files: 50 Number of linked Condition files: 9 (Up to 5 file for titration files) |
| Condition files |
Titration parameter files: 50 files (Method, Constant, Mode files) |
| Method parameters |
Parameters for each titration mode: 50 files |
| Constant parameters |
Parameters for concentration calculation: 50 files |
| Control mode file |
Standard files: 50 files
Neutralization value in petro.File : 50files
Manufacturer preinstalled modes (0 to 11), user defined modes (20 to 49) |
| Sample files |
99 files (Sample No., ID code, Master file and sample size) |
| Auto- input function |
Automatic input of blank, factors, concentration measurement results, etc. |
| Calculation |
Concentration calculation, statistics calculation, pH automatic compensation |
| Data capacity |
[COM-1700] Main unit memory: 100 data
USB flash memory (within 256MB), Max. capacity approx. 9,900 data
[COM-1750] 255 data/folder (For total memory data, if hard disc space is 1GB or more, Max. capacity approx. 9,900 data) |
| GLP support functions |
Buret precision check, electrode check, Buret use frequency, electrode maintenance, remaining reagent level |
| Buret |
Expandable up to 10 burets (per 1 titration station) |
| Automatic sample changer |
[COM-1700, TS-1700] 1 set of C-1700 sample changer can be attached. |
| Printer |
[COM-1700] Bulit-in thermal printer (paper width 58mm) [COM-1750] Color printer for A4-size paper |
| External output |
[COM-1700] RS-232C: 1 port / LAN: 1 port/USB(*1)
[COM-1750] RS-232C: 1 port / LAN: 1 port/USB (depends on PC) |
| Attached electrodes |
·GE-101B Glass combination electrode ·RE-201 Reference electrode
(provided with COM-1700 / TS-1700) |
| Power supply / Power consumption |
[COM-1700] AC 100 - 240V, 50/60 Hz, 60 VA
[COM-1700] AC 100 - 240V, 50/60 Hz, 220 VA |
| Dimensions / Weight |
[COM-1700] 250(W) x 400(D) x 150(H) mm Approx. 6.0 kg [COM-1750] depends on PC configured with |
|
|
| |
*1:The USB port on the COM-1700 main unit is only for use of USB flash memory for data storage. please do not connect other USB-type devices. |
| |
Buret B-1700 / Titration Station TS-1700 |
|
|
| Item |
Specifications |
| Display operation |
B-1700: Purge switch, LED lighting-up during dispensing TS-1700: Operation switch (LCD touch panel, wired remote controller) |
| Buret capacity |
20 mL clear glass syringe (standard) (Options: 1,5,10,50 mL syringe) |
| Cylinder cover |
UV shield (material: acrylic) for 5,10,20 mL cylinder only |
| Fabrication method |
5, 10, 20, and 50 mL: Inner cylinder precision grinding 1 mL: Outer cylinder precision grinding |
| Wet material |
PTFE, hard glass, ceramic |
| Connection tube |
2 x 3 mm, PTFE tube (brown) |
| Reagent bottle |
500 mL glass bottle (brown) |
| Selector valve |
Automatic switching with ceramic joint, Drive motor: pulse motor |
| Dispensing rate |
Full volume: 50 - 250 sec, in 50 sec, step selting (20 mL cylinder) |
| Aspritating rate |
Full volume: 25 sec |
| Minimum volume of titrant |
1.25 μL (20 mL cylinder) |
| Buret precision |
Accuracy: within ±0.1 % (full discharge of 20 mL cylinder) Repeatability: within 0.01 mL (full discharge of 20 mL cylinder, SD for n = 6) |
| Linkable buret number |
[TS-1700] Connectable up to 9 units of B-1700 |
| Measurement unit |
[TS-1700] Any one of S-1700, M-1700, P-1700, or E-1700 attached |
| Automatic sample changer |
[TS-1700] 1set of C-1700 can be attached. |
| Attached electrodes |
[TS-1700] GE-101B Glass electrode, RE-201 Reference electrode |
| Power requirements |
AC 100 to 240V , 50VA |
| Dimensions / Weight |
[B-1700] 104(W) x 240 (D) x 410(H) mm
Approx. 4.0 kg (w/ Buret head (without reagent bottle) [TS-1700] 104(W) x 325 (D) x 410(H) mm Approx. 5.5 kg (w/ Measurement unit, Buret head(without reagent bottle)) |
|
|
| |
Stirrer K-2000T2 |
|
|
| Item |
Specifications |
| Beaker |
Up to 500 mL standard beaker |
| Stirring method |
Magnetic stirrer |
| Stirring bar |
8 x 30 mm, PTFE-coated magnet (1 piece attached) |
| Rotation speed selting |
Adjustable resistor |
| Number of attachable electrode & buret tip |
1. Electrodes: Up to 2 2. Thermister electrode: 1 3. Buret tip: Up to 3 4. Dispenser nozzle: 1 |
| Power requirements |
DC 12V (power supplied from the titrator main unit) |
| Dimensions / Weight |
110(W) x 210(D) x 350(H) mm Approx. 1.0 kg |
|
|
 |
Options |
 |
| Model |
| For Potentimetric titration S-1700 |
| For Photometric Titration M-1700 |
| For Polarization Titration P-1700 |
| For Conductometric Titration E-1700 |
| Dot Impact Printer PR-302B |
Paper width:58mm |
| Automatic samle changer C-1712 |
|
 |
| |
* |
The product color may vary from the actual product due to printing qualities. |
|
| |
* |
Appearance, specification, etc. are subject to change for improvement without prior notice. |
|
| |
Note: For safe and appropriate use, please be sure to read the "Instruction Manual" before using the product. |
|
 |
 |
















|