| Item |
Specifications |
| 5°specular reflectance accessory (relative) |
Relative reflectivity at an incident angle of 5°can be measured for a standard sample. |
| Vertical 5°specular reflectance accessory (relative) |
Relative reflectivity at an incident angle of 5°can be measured for a standard sample. Compared with a 5° regular reflector (relativity), a large sample or a sample difficult to fix because of its shape can also be measured. |
| 5°specular reflectance accessory (absolute) |
Absolute reflectivity at an incident angle of 5° can be measured. |
| Small 5°specular reflectance accessory (absolute) |
Using a holder, absolute reflectivity at an incident angle of 5° can be measured for a microscopic sample. |
| 12°specular reflectance accessory (absolute) |
Absolute reflectivity at an incident angle of 12° can be measured. (A polarizer and a polarizer holder are provided separately) |
| 30°specular reflectance accessory (absolute) |
Absolute reflectivity at an incident angle of 30° can be measured. (A polarizer and a polarizer holder are provided separately) |
| 45°specular reflectance accessory (absolute) |
Absolute reflectivity at an incident angle of 45° can be measured. (A polarizer and a polarizer holder are provided separately) |
| Polarizer holder (holder alone) |
Needed when measuring reflectivity at an incident angle of 12° or more. (A polarizer is provided separately.) |
| High-sensitivity integrating sphere accessory |
φ60 integrating sphere has an inner surface coated with Spectralon. Compared with a standard integrating sphere, the ultraviolet region can be measured with less noise. |
| φ60 full-sphere integrating sphere accessory |
The integrating sphere is effective when light flux expands after passing through a sample, for example in the measurement of transmittance of a lens. |
| Prism measurement unit |
Absolute reflectivity and transmittance can be measured at an incident angle of 45° for a cubic prism (16-60mm). |
| Small prism measurement unit |
Absolute reflectivity can be measured at an incident angle of 45° for a micro-cubic prism (5-20mm). |
| Variable angle absolute reflectance accessory (10° to 60°) |
Absolute reflectivity can be measured at incident angles of 10-60° for every 10°. |
| Variable angle absolute reflectance accessory (15° to 65°) |
Absolute reflectivity can be measured at incident angles of 15-65° for every 10°. |
| Variable angle reflectance accessory (relative) |
Relative reflectivity of a sample can be measured at an arbitrary incident angle (20-60°). |
| Variable angle transmittance measurement accessory |
Transmittance can be measured at an arbitrary incident angle (0-60°) using a rotational stage. |
| Lens transmittance measurement accessory |
Lens transmittance can be measured. |
| Large lens transmittance measurement accessory |
The transmittance of a large lens can be measured with a V bench. |
| Glass filter holder |
Transmittance and absorbance of a plate-like solid sample, like a glass filter, can be measured. |
| Film holder |
A film-like sample can be measured. |